B2200E Series
4" Frame Depth
Blast-Resistant Aluminum
Window
Type
Frame Depth
(inches)
Series
Designed Blast
Pressure
(psi)
Positive Phase
Impulse
(psi-msec)
Window Size
(inches)
Glazing
Composition
(inches)
Testing & Certifications
Test Methods
Qualified
Certification
Double Hung
(Side-Load)
4
B2200E
6
42
50 x 68
1
⁄
4
ann,
1
⁄
2
spacer,
1
⁄
4
lami
ASTM F 1642
ASTM “Minimal Hazard”
GSA Condition 3b
UFC 4-010-01
Independent Certification Program
Click here for GSA Performance
Click here to download drawings,
specifications and product literature.
STANDARD B2200E FEATURES
Double Hung Side-Load windows for bomb blast mitigation
Provides GSA level C protection against explosive attacks
Meets DoD UFC 4-010-01 criteria
Utilizes standard locking hardware
Trim & clip or receptor anchoring system
1” insulating glass construction using industry standard
laminated technology
Mulls to 4” frame fixed and operable products
Sash easily removes from frame for maintenance & cleaning
Removable take-out clips to prevent unauthorized sash removal
Full-length extruded lift handles
Exterior beveled glazing leg (putty-glazed look)
Products
Technical
Specialty Products
About Graham
GThurm
Hung
Casement
Sliding
Doors
Curtain Wall
Downloads
LEED Info
Manuals
Glossary
Product Selector
Color Selection Chart
Blast
Hurricane
Acoustical
Accessories
Sunshades
Security/Vandal Screen
Graham Video
Projects
Find a Rep
Contact Us
Careers
SITE MAP
Proud Members of: