Graham Architectural Products
  home - casement/projected menu - 6600 series
  CASEMENT / PROJECTED
SERIES 6600 Casement / Projected
Models of Series 6600
Model 6600
2 1/4" Frame Depth
Maximum Test Size:
Casement-3' x 5' , Projected-5'x 3'

Standard Features
  • Integral and fixed stack mull for minimal sight-lines
  • Mulls horizontally or vertically to 2 1/4" frame fixed
         and operable products
  • Strap anchor, receptor and panning
         systems available for installation
  • Flush design of vent & frame for aesthetic appeal
  • .125" wall thickness; unrestricted wall
         thickness available





  • Optional Features
  • Dual glazed design offers optional:
             - High performance glazing combinations
             - Integral mini blinds
             - Impact resistant polycarbonate lite
  • Stainless steel projected or aluminum butt-hinged
         hardware
  • Hardware options to limit vent access
         to custodial use
  • Special hardware and glazing for hospital use
  • In-swing or out-swing on operable units
  • Custom nail fins for commercial new construction
  •   Pacific Regent
      La Jolla, Ca

     MODELS - SERIES 6600 CASEMENT / PROJECTED
      PERFORMANCE DOWNLOADS
    BASE MODEL AAMA RATING AIR INFILTRATION* WATER-PSF U-FACTOR CRF Specification Document
    6600 C-AW130 0.03 25.00 0.58-0.43 55 Structural Test Report: C-AW130
    6600 C-HC130 0.03 25.00 0.58-0.43 55 Structural Test Report: C-HC130
    6600 AP-AW70 0.03 12.00 0.59-0.43 55 Structural Test Report: AP-AW70
    6600 AP-HC70 0.03 12.00 0.59-0.43 55 Structural Test Report: AP-HC70
    6600 F-AW110 0.01 25.00 0.58-0.43 55 Structural Test Report: F-AW110
      * AW tests conducted at 50 mph.
      DRAWINGS for Model 6600 Download drawings for model get i-drop plug-in   
    DESCRIPTION PREVIEW
    DRAWING
    DOWNLOAD
    PDF
    DOWNLOAD
    DRAWING
    I-DROP
    Model 6675 Projected - 2 1/4in.
    Model 6675 Projected - 2 1/4in.
        b_65_21.dwg
    Model 6675 Fixed / Projected 2 1/4in.
    Model 6675 Fixed / Projected 2 1/4in.
        b_65_22.dwg
    Model 6675 Projected / Projected - 2 1/4in.
    Model 6675 Projected / Projected - 2 1/4in.
        b_65_23.dwg
    Model 6675 Casement - 2 1/4in.
    Model 6675 Casement - 2 1/4in.
        b_65_24.dwg
    Model 6675 Fixed/Casement - 2 1/4in.
    Model 6675 Fixed/Casement - 2 1/4in.
        b_65_25.dwg
    Model 6675 Projected - 2 1/4in.
    Model 6675 Projected - 2 1/4in.
        b_65_26.dwg
    Model 6675 Fixed/Projected 2 1/4in.
    Model 6675 Fixed/Projected 2 1/4in.
        b_65_27.dwg
    Model 6675 Projected / Projected - 2 1/4in.
    Model 6675 Projected / Projected - 2 1/4in.
        b_65_28.dwg
    Model 6600 Casement - 2 1/4in.
    Model 6600 Casement - 2 1/4in.
        b_65_29.dwg
    Model 6675 Fix/Casement - 2 1/4in.
    Model 6675 Fix/Casement - 2 1/4in.
        b_65_30.dwg
    Model 6600 Fixed/Fixed - 2 1/4in.
    Model 6600 Fixed/Fixed - 2 1/4in.
        b_65_31.dwg
    Model 6675 Projected / Projected - 2 1/4in.
    Model 6675 Projected / Projected - 2 1/4in.
        b_65_32.dwg
    Installation Accessories - 2 1/4in.
    Installation Accessories - 2 1/4in.
       b_ac_01a.dwg
    Installation Accessories - 2 1/4in.
    Installation Accessories - 2 1/4in.
       b_ac_01b.dwg
    Installation Accessories - 2 1/4in.
    Installation Accessories - 2 1/4in.
       b_ac_01c.dwg
     
       BACK TO TOP
    1551 Mount Rose Avenue York, Pennsylvania 17403-2909   phone: 717-849-8100      toll-free: (800) 755-6274      info@grahamwindows.com
    company information  -  projects  -  what's new  -  contact us  -  product literature  -  technical resources  -  home