printPrint this page

Aegis Security Screen

Security & Vandal Screens
Frame Depth (inches)
Description Medium & Heavy Duty Security Screen for Windows

B0300 Horizontal Sliding

Horizontal Sliding Window
Frame Depth (inches) 3.25
Description Blast resistant architectural grade 3-1/4" horizontal sliding window
Test Size (inches)66 x 48
Condition/Hazard ResponseMinimal
Design Blast Pressure (psi)6 psi
Positive Phase Impulse (psi-msec)42 psi-msec
Test MethodASTM F 1642

B0360 Series Horizontal Sliding

Horizontal Sliding Window
Frame Depth (inches) 3.25
Description Blast resistant 3-1/4" fixed over horizontal sliding window
Test Size (inches)Various
Condition/Hazard ResponseUFC & GSA Calculated
Design Blast Pressure (psi)Blast Evaluated
Positive Phase Impulse (psi-msec)Blast Evaluated
Test MethodUFC & GSA Calculated
Frame Depth (inches) 4.0
Description Blast resistant architectural grade 4-1/2" sliding glass door
Test Size (inches)72 x 84
Condition/Hazard ResponseN/A
Design Blast Pressure (psi)Minimum UFC 4-010-01
Positive Phase Impulse (psi-msec)Minimum UFC
Test MethodUFC Calculation
Frame Depth (inches) 3.25
Description Blast resistant architectural grade 3-1/4" fixed window system with nail fin frame.
Test Size (inches)49.75 x 67.75
Condition/Hazard ResponseN/A
Design Blast Pressure (psi)Minimum UFC 4-010-01
Positive Phase Impulse (psi-msec)Minimum UFC
Test MethodUFC Calculation
Frame Depth (inches) 3.25
Description Blast resistant architectural grade 3-1/4" fixed window system.
Test Size (inches)48 x 66
Condition/Hazard ResponseMinimal
Design Blast Pressure (psi)6.1 psi
Positive Phase Impulse (psi-msec)41 psi-msec
Test MethodASTM F 1642
Frame Depth (inches) 4.0
Description Blast resistant architectural grade 4" fixed window system
Test Size (inches)48 x 66
Condition/Hazard ResponseMinimal
Design Blast Pressure (psi)6.7 PSI
Positive Phase Impulse (psi-msec)47 psi-msec
Test MethodASTM F1642
Frame Depth (inches) 3.25
Description Blast resistant architectural grade 3-1/4" single hung window with nail fin frame.
Test Size (inches)45.50 x 63.375
Condition/Hazard ResponseMinimal
Design Blast Pressure (psi)6.6 psi
Positive Phase Impulse (psi-msec)48 psi-msec
Test MethodASTM F 1642
Frame Depth (inches) 3.25
Description Blast resistant architectural grade 3-1/4" single hung window
Test Size (inches)48 x 66
Condition/Hazard ResponseMinimal
Design Blast Pressure (psi)4.4 psi
Positive Phase Impulse (psi-msec)34.3 psi-msec
Test MethodASTM F 1642
Frame Depth (inches) 4.0
Description Blast resistant architectural grade 4" double hung window
Test Size (inches)49.75 x 67.75
Condition/Hazard ResponseLow
Design Blast Pressure (psi)6.2 psi
Positive Phase Impulse (psi-msec)42 psi-msec
Test MethodASTM F 1642
Frame Depth (inches) 3.25
Description Blast resistant architectural grade 3-1/4" single hung window
Test Size (inches)36 x 72
Condition/Hazard ResponseN/A
Design Blast Pressure (psi)Meets DoD UFC 4-010-01 Criteria
Positive Phase Impulse (psi-msec)Minimum UFC
Test MethodUFC Calculation

B6500 Series Projected

Projected Window
Frame Depth (inches) 2.25
Description Blast resistant architectural grade 2-1/4" projected window
Test Size (inches)48 x 66
Condition/Hazard ResponseMinimal
Design Blast Pressure (psi)5.9 psi
Positive Phase Impulse (psi-msec)48 psi-msec
Test MethodASTM F 1642

B6500 Series Casement

Casement Window
Frame Depth (inches) 2.25
Description Blast resistant architectural grade 2-1/4" casement window
Test Size (inches)48 x 66
Condition/Hazard ResponseMinimal
Design Blast Pressure (psi)5.9 psi
Positive Phase Impulse (psi-msec)48 psi-msec
Test MethodASTM F 1642

B6500 Series Fixed

Fixed Window
Frame Depth (inches) 2.25
Description Blast resistant architectural grade 2-1/4" fixed window
Test Size (inches)48 x 66
Condition/Hazard ResponseMinimal
Design Blast Pressure (psi)6.4 psi
Positive Phase Impulse (psi-msec)48 psi-msec
Test MethodASTM F 1642
Frame Depth (inches) 2.25
Description Blast resistant architectural grade 2-1/4" casement window that installs inboard of existing window.
Test Size (inches)48 x 85
Condition/Hazard ResponseMinimal
Design Blast Pressure (psi)7 psi
Positive Phase Impulse (psi-msec)44 psi-msec
Test MethodASTM F 1642

B6500IBG Twin Casement

Casement Window
Frame Depth (inches) 2.25
Description Blast resistant architectural grade 2-1/4" casement window that installs inboard of existing window.
Test Size (inches)88 x 96.75
Condition/Hazard ResponseNo Break
Design Blast Pressure (psi)5.3 psi
Positive Phase Impulse (psi-msec)32.8 psi-msec
Test MethodASTM F 1642

B6600 Series Casement

Casement Window
Frame Depth (inches) 2.25
Description Blast resistant architectural grade 2-1/4" casement window with an unrestricted nominal wall thickness
Test Size (inches)48 x 66
Condition/Hazard ResponseMinimal
Design Blast Pressure (psi)6.5 psi
Positive Phase Impulse (psi-msec)48 psi-msec
Test MethodASTM F 1642

B6600 Series Fixed

Fixed Window
Frame Depth (inches) 2.25
Description Blast resistant architectural grade 2-1/4" fixed window with an unrestricted nominal wall thickness
Test Size (inches)48 x 66
Condition/Hazard ResponseMinimal
Design Blast Pressure (psi)6.1 psi
Positive Phase Impulse (psi-msec)46 psi-msec
Test MethodASTM F 1642

B6600 Series Projected

Projected Window
Frame Depth (inches) 2.25
Description Blast resistant architectural grade 2-1/4" projected window with an unrestricted nominal wall thickness
Test Size (inches)48 x 66
Condition/Hazard ResponseMinimal
Design Blast Pressure (psi)6.5 psi
Positive Phase Impulse (psi-msec)48 psi-msec
Test MethodASTM F 1642

B6800 Casement

Casement Window
Frame Depth (inches) 3.5
Description Blast resistant architectural grade 3-1/2" casement window
Test Size (inches)49.75 x 67.75
Condition/Hazard ResponseMinimal
Design Blast Pressure (psi)6 psi
Positive Phase Impulse (psi-msec)42 psi-msec
Test MethodASTM F 1642

B6800 Fixed

Fixed Window
Frame Depth (inches) 3.5
Description Blast resistant architectural grade 3-1/2" fixed window
Test Size (inches)49.75 x 67.75
Condition/Hazard ResponseMinimal
Design Blast Pressure (psi)5.8 psi
Positive Phase Impulse (psi-msec)41 psi-msec
Test MethodASTM F 1642

B6800 Projected

Projected Window
Frame Depth (inches) 3.5
Description Blast resistant architectural grade 3-1/2" projected window
Test Size (inches)49.75 x 67.75
Condition/Hazard ResponseMinimal
Design Blast Pressure (psi)6 psi
Positive Phase Impulse (psi-msec)42 psi-msec
Test MethodASTM F 1642
Frame Depth (inches) 3.5
Description High performance blast resistant architectural grade 3-1/2" casement & projected window
Test Size (inches)49.75 x 67.75
Condition/Hazard ResponseLow
Design Blast Pressure (psi)10.8 & 23.5 psi
Positive Phase Impulse (psi-msec)96 & 100 psi-msec
Test MethodASTM F 1642
Frame Depth (inches) 3.5
Description High performance blast resistant architectural grade 3-1/2" fixed window
Test Size (inches)49.75 x 67.75
Condition/Hazard ResponseNo Break
Design Blast Pressure (psi)10.4 & 24.2 psi
Positive Phase Impulse (psi-msec)91 & 116 psi-msec
Test MethodASTM F 1642

B7500 Series Dual Action

Dual Action Window
Frame Depth (inches) 2.25
Description Blast resistant 2-1/4" dual action window
Test Size (inches)48.50 x 66.63
Condition/Hazard ResponseVery Low
Design Blast Pressure (psi)6.2 psi
Positive Phase Impulse (psi-msec)43 psi-msec
Test MethodASTM F 1642

BR6800 Fixed

Fixed Window
Frame Depth (inches) 3.5
Description Ballistic resistant architectural grade 3-1/2" fixed window
Test MethodUL752 Level 3

S6300 Series Casement

Casement Window
Frame Depth (inches) 4.0
Description 4" frame depth thermal strutted human impact casement window with specially designed hardware and glazing system for hospital and psychiatric applications.
U-Value0.39
AAMA RatingAW-PG130
Test Size (inches)36 x 60
Air Infiltration (cfm/ft2)0.05
Water Resistance (psf)12.11
Design Pressure Positive (psf)130.33

S6300 Series Fixed

Fixed Window
Frame Depth (inches) 4.0
Description 4" frame depth thermal strutted human impact fixed window with specially designed hardware and glazing system for hospital and psychiatric applications.
U-Value0.39
AAMA RatingAW-PG95
Test Size (inches)62 x 99
Air Infiltration (cfm/ft2)0.1
Water Resistance (psf)12
Design Pressure Positive (psf)95